Class CB Automatic Transfer Switch with Overcurrent Release for AC220V and AC380V Systems
   
   
  Class CB
 ATSE with overcurrent release
 Its main contact can be closed and used to break short-circuit current
 WATSN series automatic transfer switch is a class CB automatic transfer switch if it
 adopts a circuit breaker with overcurrent release as the actuator. With selective
 protective function, it can provide short-circuit and overload protection for
 downstream loads and cables. Its making and breaking capacity is significantly
 higher than other components such as contactors and relays.
   
  
   
    
   
   Wide application
  ● Used in AC220V and AC380V systems
  ● Three operation modes configurable on the site: automatic change and automatic
  recovery, automatic change without automatic recovery, and mutual standby.
  ● Can be easily connected to a smart monitoring system
  High-performance product
  ● High breaking capacity (class CB)
  ● Operation breaking capacity is equal to 100% of ultimate breaking capacity (class
  CB)
  ● Provide high current-limiting capacity and total economic selectivity (class CB)
  ● Provide high short-circuit making capacity and rated short-time withstand capacity
  (class PC)
  Easy connection and installation
  ● No need to derate in both horizontal and vertical installation
  ● No need to derate for lower incoming lines
  Higher reliability
  ● Alarm for wrong neutral connection
  ● Automatic signal cutoff in case of unsuccessful transfer
  Smart communication
  ● RS485 communication interface and Modbus-RTU communication protocol
  ● Provide four remote functions including telecommand, telemetry, telecontrol, and
  telereg
     
  Notes:
 Controller types include: A - Terminal type; B - Basic Type; D- Smart type
 Frame current levels: 63, 100, 160, 250, 400, 630, 800, 1000, 1250, 1600
 Rated current: Depending on different frame levels, the release is selected by the user (by making reference to NSX/NS circuit breaker sample)
 Selectable number of poles: 2 (only for iC65 series), 3, 4 (all series)
 Electric device Class: CB - with short-circuit and overload protection
 Operation modes: R - Automatic change and automatic recovery; S - Automatic change without automatic recovery; I - Mutual standby
 Additional functions: X- Fire protection linkage; F- Feedback signal; I - Current monitoring module (only available for Type D controller)
 Release – class CB. Release with different protection range can be selected based on user needs.
 *: Two installation methods can be provided: Device-mounted and panel-mounted.
 Please add a note if panel installation is required. iC65 products do not support
 panel-mounted controllers.
 **: F- Feedback signal function (including position feedback and alarm feedback, please add explanatory text if necessary).800-1600A series products include a group of position feedback and a group of alarm feedback as standard. For 63A and lower current products, only a group of position feedback is available.
   
   
            
        
            
                
                                    Product Tags:
                                              
                                          
                                          
                                
                
                    
                                             
                                         | 
                
                
                    | 
                         
                             
                                                                Class CB Automatic Transfer Switch with Overcurrent Release for AC220V and AC380V Systems Images
                                                            
                        
                     |